Linear vs. Switching Power Supplies: A Headphone Amplifier Laboratory Test

Written by

in

Bench study · GraceNote Audio · November 2026

Question: Does replacing a toroidal linear supply with a low-cost switching adapter cause a measurable change in the harmonic distortion of a discrete two-stage headphone-amplifier test assembly?

To answer it, we tested the same OPA1612 → OPA1622 amplifier with three power configurations, using the same external sine-wave generator, the same 300 Ω load, and the same Keithley 2015 / Rigol DS2072A instruments. The most visually dramatic result came from the oscilloscope: the low-cost adapter produced a considerably spikier trace. The measured audio-frequency THD, however, stayed close to the generator’s own THD under these conditions.

Key result: The three test supplies produced closely matched output levels and displayed THD at the tested signal level. This does not prove equal noise performance, inaudibility of switching interference, or the intrinsic THD of the amplifier.

The amplifier and measurement point

The device under test uses an OPA1612 voltage-gain stage followed by an OPA1622 headphone-output stage. The assembly is mounted with a separately built headphone-protection PCB. The output was measured across a 300 Ω dummy-load resistor connected directly to the OPA1622 output, before the protection relay. This excludes the relay contacts and headphone socket from the electrical measurement path.

OPA1612/OPA1622 amplifier module mounted on the headphone protection PCB
GraceNote Audio OPA1612/OPA1622 amplifier under test, with the protection board behind it
300-ohm test resistor connected to the OPA1622 output ahead of the protection relay
The 300 Ω dummy load is connected to the OPA1622 output ahead of the protection relay

The generator was connected directly to the amplifier input, with no volume potentiometer in the test path. At 1 kHz, the Rigol measured approximately 102.7 mV RMS on the input. At that frequency, the Keithley output reading with toroidal power was 382.25 mV RMS, corresponding to a measured voltage gain of approximately 3.72× (11.4 dB).

At roughly 0.382 V RMS across 300 Ω, the test load dissipates only about 0.49 mW. These are low-level performance measurements, not a maximum-power or thermal-stress test.

The three power-supply configurations

1. Toroidal linear reference

An Avel Lindberg Y236203 50 VA, 2 × 15 V AC toroidal transformer feeds rectification, reservoir capacitors, and an LM317/LM337 dual-rail regulator board. The amplifier rails were measured near +12.88 V and −12.88 V. This is the reference condition.

Avel Lindberg Y236203 50VA toroidal transformer and LM317 LM337 regulator board
Linear reference supply: Avel Lindberg 50 VA toroid and LM317/LM337 regulator board

2. HP/Delta adapter and switching conversion

A Hewlett-Packard OmniBook F1454A adapter, made by Delta Electronics and rated 19 V DC / 3.16 A, feeds the two-rail TPS5430 conversion module and the same LM317/LM337 post-regulation architecture. Under amplifier load, the rails were measured at +12.84 V and −12.74 V. This configuration was checked at 1 kHz only.

Hewlett Packard OmniBook HP F1454A Delta 19V 3.16A AC DC power supply label
The HP/Delta 19 V, 3.16 A adapter used for the 1 kHz switching-supply control
TPS5430 dual-rail DC DC board wired to LM317 LM337 post-regulation module
TPS5430 conversion module connected to the LM317/LM337 linear post-regulator board

3. Generic adapter and switching conversion

The third source was an inexpensive unbranded Model 1810 wall adapter, labelled 18 V DC / 1 A, feeding the TPS5430 module and LM317/LM337 regulators. This is a deliberately practical, inexpensive test case—not an optimized laboratory supply. The specific TPS5430 module was kept within its intended 15 V-per-rail output limit; no attempt was made to raise its operating voltage.

Unbranded model 1810 power adapter 18V 1A label
Generic 18 V, 1 A adapter: the deliberately inexpensive real-world supply

The LM317/LM337 modules use fixed resistor values in this build. Their settings were not adjusted between the switching-supply tests. The toroidal reference rail values and the HP/Delta rail values were documented; the corresponding rail values for the generic-adapter run should not be assumed identical without a direct reading.

How the measurements were made

  • Signal: sine waves at 100 Hz, 1 kHz, and 10 kHz, with the generator amplitude setting unchanged across the supply tests; only the frequency was selected.
  • Output load: 300 Ω, measured before the headphone-protection relay.
  • Keithley 2015: output AC RMS and harmonic-distortion percentage. The harmonic window was 2nd through 10th at 100 Hz and 1 kHz; 2nd through 4th at 10 kHz.
  • Rigol DS2072A: output waveform, RMS and peak-to-peak voltage. Oscilloscope Vpp includes any transient spikes and pickup that appear within the measurement bandwidth.
  • Signal source control: THD was also measured directly at the output of the generator, rather than assuming a distortion-free source.

Only the 1 kHz input RMS was directly verified at the amplifier input in the reference series. Consequently, the very small variations in output RMS across frequency should not be presented as a precision frequency-response measurement.

Results: output signal level

Supply and output AC RMS100 Hz1 kHz10 kHz
Toroid + LM317/LM337381.49 mV382.25 mV382.26 mV
HP/Delta + TPS5430 + LM317/LM337—382.02 mV—
Generic 18 V + TPS5430 + LM317/LM337381.15 mV382.05 mV381.73 mV
Plot of measured 300 ohm output RMS for toroid and generic adapter
The output signal level remains within roughly 1 mV across the measured conditions.

Across the toroidal and generic-adapter runs, the Keithley output readings differed by less than 1 mV. The HP/Delta 1 kHz control was similarly close to the toroidal 1 kHz reference. This shows consistent measured output level at the selected test amplitudes, not necessarily identical internal noise or regulation under heavier loads.

Results: harmonic distortion

Supply and measured output THD100 Hz
(2–10)
1 kHz
(2–10)
10 kHz
(2–4)
Toroid + LM317/LM3370.208%0.212%0.186%
HP/Delta + TPS5430 + LM317/LM337—0.212%—
Generic 18 V + TPS5430 + LM317/LM3370.208%0.210%0.182%
Generator alone0.226%0.212%0.186%
Grouped comparison of measured output THD for toroid and generic adapter at 100Hz 1kHz and 10kHz
Measured THD at the output. All values include distortion from the external signal generator.

At 1 kHz, the toroid and HP/Delta setups both displayed 0.212% THD, while the generic adapter displayed 0.210%. The difference of 0.002 percentage points is too small to interpret as a meaningful improvement or degradation without repeated runs and an uncertainty analysis. At 100 Hz, the toroid and generic adapter both displayed 0.208%. At 10 kHz, the figures were 0.186% and 0.182%, respectively.

Keithley 2015 THD 0.212 percent toroidal power 1kHz
Keithley 2015: 0.212% measured THD at 1 kHz with the toroidal supply
Keithley 2015 THD 0.212 percent HP Delta TPS5430 power 1kHz
Keithley 2015: 0.212% measured THD at 1 kHz with HP/Delta plus TPS5430
Keithley 2015 THD 0.210 percent generic adapter TPS5430 1kHz
Keithley 2015: 0.210% measured THD at 1 kHz with the generic adapter

Critical limitation: The generator alone measured 0.226% THD at 100 Hz, 0.212% at 1 kHz, and 0.186% at 10 kHz. These source figures are comparable to the amplifier-output readings, so the setup cannot isolate the amplifier’s intrinsic THD. Harmonic components can add or cancel in phase, and the direct source measurement was made at a different signal level from the amplifier output. The displayed output THD must therefore be reported as THD of the generator-plus-amplifier measurement chain.

Also, a 10 kHz THD result limited to harmonics 2–4 cannot be compared directly with the 100 Hz and 1 kHz results that include harmonics 2–10 as though the analyzer used the same harmonic span.

What the oscilloscope revealed

Although the Keithley readings were remarkably consistent, the Rigol told a different visual story. The generic adapter produced pronounced narrow spikes and a thicker-looking trace, particularly around the negative portions of the sine wave. This increased the indicated peak-to-peak voltage (Vpp) even when the Keithley AC RMS reading hardly moved.

FrequencyToroid VppGeneric adapter Vpp
100 Hz1.232 V1.440 V
1 kHz1.192 V1.456 V
10 kHz1.184 V1.392 V

100 Hz: oscilloscope comparison

Rigol 100Hz output sine wave with toroidal power supply
100 Hz output waveform with toroidal power: 1.232 Vpp on the oscilloscope
Rigol 100Hz output sine wave with generic 18V adapter and TPS5430
100 Hz with the generic adapter: wider spikes and 1.440 Vpp indicated

10 kHz: oscilloscope comparison

Rigol 10kHz sine output toroidal supply reference
10 kHz waveform with toroidal power: 1.184 Vpp indicated
Rigol 10kHz output sine wave with generic adapter TPS5430
10 kHz waveform with the generic adapter: 1.392 Vpp indicated

Why Vpp is not THD: Peak-to-peak capture responds to occasional fast transients. A harmonic-distortion measurement, by contrast, tracks selected harmonics of the fundamental tone. Switching ripple, broadband noise, ground-loop pickup and probe-induced interference can all alter an oscilloscope trace without necessarily increasing the harmonics reported by the Keithley.

Our earlier probing also showed that much of the observed RF activity depends on the grounding arrangement of the oscilloscope probe: even a shorted tip could display switching-related pickup when connected to the amplifier ground. Therefore, the additional spikes must not be described as a fully verified increase in actual headphone-output noise without a controlled probe-ground baseline and an appropriately band-limited noise test.

An OPA1622 design detail worth investigating

The OPA1622 board in this build uses an unusual local reference point: its dedicated GND/reference pin connects to a midpoint derived from two 10 kΩ resistors between the positive and negative rails, with 0.1 µF bypass capacitors. The OPA1612 has no equivalent dedicated GND pin. This feature may affect how the circuit responds to supply-borne high-frequency interference, but the present test does not establish that it improves THD or suppresses noise. It is a hypothesis for a separate, controlled experiment.

Conclusions and what remains untested

  • No meaningful change in displayed THD was established: at 100 Hz, 1 kHz and 10 kHz, the measured figures were close across the toroid and generic-adapter supplies.
  • Output signal levels were highly consistent: Keithley output AC RMS readings clustered around 0.382 V at 300 Ω.
  • Scope traces were not equivalent: the generic adapter produced noticeably more peak activity and higher Vpp readings.
  • This is not a noise-floor comparison: a 20 MHz oscilloscope bandwidth limit does not constitute an audio-band noise measurement, and THD alone does not establish THD+N or audible transparency.
  • The signal generator is a limiting factor: source THD was comparable to the measured amplifier-output THD. A cleaner source and repeatability study would be needed to characterize the amplifier itself.

Bottom line: In this low-level, 300 Ω load experiment, even an inexpensive 18 V wall adapter followed by TPS5430 conversion and LM317/LM337 post-regulation did not produce a clearly measurable THD penalty relative to the toroidal reference. The RF spikes seen on the oscilloscope deserve additional investigation; they are not, by themselves, proof of degraded audio-band distortion.

All measurements and photographs in this report were taken on the actual GraceNote Audio bench setup. This article documents one prototype and one set of test conditions; it is not a universal statement about switching versus linear power supplies.