For this GraceNote Audio experiment, we compared two power-supply approaches using the same OPA1622 headphone amplifier. The amplifier and test conditions remained unchanged; only the power source was different.
Two Ways to Power the Same Amplifier
The first option uses a traditional Avel Lindberg Y236203 toroidal transformer rated at 50 VA.
The second uses a compact Hi-Link HLK-10M15B switching module rated at 15 V, 0.67 A and 10 W, followed by linear regulation.
Traditional power supply — Avel Lindberg Y236203, 50 VA.Compact switching supply — HLK-10M15B with linear regulation.
The same OPA1622 amplifier board was used for both power-supply configurations.
The comparison used the same 100 mV test-signal setting and a 200 Ω load. Measurements were performed at three frequencies: 100 Hz, 1 kHz and 10 kHz.
Could an ordinary metal coffee tin help reduce unwanted interference from a toroidal transformer?
We tried this simple experiment by placing an empty metal coffee tin over the transformer and comparing the spectrum with and without the cover.
An ordinary coffee tin becomes part of an unexpected transformer-shielding experiment.
The spectrum showed a change, with some unwanted interference components reduced. The cover did not eliminate all interference, but the experiment demonstrated an interesting practical possibility.
Sometimes an unexpected solution can be found in an everyday object.
We also checked the amplifier with no input signal. The input was shorted to ground, and a 200 Ω load remained connected.
Both channels were checked with both power-supply configurations. The measured residual noise was approximately 1.9 µV RMS. No distinct 60 Hz component stood out in the spectra.
Transformer Shielding
Another part of the experiment involved placing a metal cover over the toroidal transformer.
Comparing the spectra with and without the cover showed a reduction in some unwanted interference components. Metal shielding can help reduce transformer-related interference reaching nearby amplifier circuitry.
Measurement Comparisons
The following captures show the oscilloscope waveforms and corresponding spectra for both power-supply arrangements.
100 Hz
Toroidal transformer — 100 Hz.Switching supply — 100 Hz.
This OPA1622 power supply comparison is not intended to establish a universal rule that one type of power supply is always better. It looks at two specific implementations connected to the same headphone amplifier.
Keeping the amplifier, test-signal setting and 200 Ω load unchanged makes it easier to compare what happened in this particular setup. Measurements at 100 Hz, 1 kHz and 10 kHz provide several points of reference, while the no-input checks on both channels add another view of the background noise.
The metal-cover experiment also explores a practical way of reducing unwanted transformer interference. Different amplifiers, circuit layouts, grounding arrangements and power-supply designs may behave differently.
The results are best understood as a comparison of these two builds, not as a verdict on every toroidal transformer or switching supply. The final choice can depend on priorities such as size, weight, energy use and listening experience.
Space, Weight and Energy
Beyond the measurements, this OPA1622 power supply comparison considers the practical trade-offs of size, weight and energy use.
A toroidal transformer is a traditional choice, but it requires space and adds weight. A compact switching supply offers an alternative for those who want to reduce the size and weight of their equipment.
Energy consumption is another consideration, particularly with electricity prices continuing to rise. The choice of power supply can also influence the long-term cost of operating audio equipment.
Two different approaches, the same amplifier. Which one would you choose?
After all those measurements, perhaps it’s time for something completely different.
This OPA1622 power supply comparison does not declare a winner; it presents two approaches and leaves the choice to the reader.
Can a $15 ultrasonic cleaner remove visible flux residue from densely populated audio circuit boards? We tested the DG-UC02 on OPA1612/OPA1622 amplifier modules and photographed the results before and after cleaning.
Question: Does replacing a toroidal linear supply with a low-cost switching adapter cause a measurable change in the harmonic distortion of a discrete two-stage headphone-amplifier test assembly?
To answer it, we tested the same OPA1612 → OPA1622 amplifier with three power configurations, using the same external sine-wave generator, the same 300 Ω load, and the same Keithley 2015 / Rigol DS2072A instruments. The most visually dramatic result came from the oscilloscope: the low-cost adapter produced a considerably spikier trace. The measured audio-frequency THD, however, stayed close to the generator’s own THD under these conditions.
Key result: The three test supplies produced closely matched output levels and displayed THD at the tested signal level. This does not prove equal noise performance, inaudibility of switching interference, or the intrinsic THD of the amplifier.
The amplifier and measurement point
The device under test uses an OPA1612 voltage-gain stage followed by an OPA1622 headphone-output stage. The assembly is mounted with a separately built headphone-protection PCB. The output was measured across a 300 Ω dummy-load resistor connected directly to the OPA1622 output, before the protection relay. This excludes the relay contacts and headphone socket from the electrical measurement path.
GraceNote Audio OPA1612/OPA1622 amplifier under test, with the protection board behind itThe 300 Ω dummy load is connected to the OPA1622 output ahead of the protection relay
The generator was connected directly to the amplifier input, with no volume potentiometer in the test path. At 1 kHz, the Rigol measured approximately 102.7 mV RMS on the input. At that frequency, the Keithley output reading with toroidal power was 382.25 mV RMS, corresponding to a measured voltage gain of approximately 3.72× (11.4 dB).
At roughly 0.382 V RMS across 300 Ω, the test load dissipates only about 0.49 mW. These are low-level performance measurements, not a maximum-power or thermal-stress test.
The three power-supply configurations
1. Toroidal linear reference
An Avel Lindberg Y236203 50 VA, 2 × 15 V AC toroidal transformer feeds rectification, reservoir capacitors, and an LM317/LM337 dual-rail regulator board. The amplifier rails were measured near +12.88 V and −12.88 V. This is the reference condition.
Linear reference supply: Avel Lindberg 50 VA toroid and LM317/LM337 regulator board
2. HP/Delta adapter and switching conversion
A Hewlett-Packard OmniBook F1454A adapter, made by Delta Electronics and rated 19 V DC / 3.16 A, feeds the two-rail TPS5430 conversion module and the same LM317/LM337 post-regulation architecture. Under amplifier load, the rails were measured at +12.84 V and −12.74 V. This configuration was checked at 1 kHz only.
The HP/Delta 19 V, 3.16 A adapter used for the 1 kHz switching-supply controlTPS5430 conversion module connected to the LM317/LM337 linear post-regulator board
3. Generic adapter and switching conversion
The third source was an inexpensive unbranded Model 1810 wall adapter, labelled 18 V DC / 1 A, feeding the TPS5430 module and LM317/LM337 regulators. This is a deliberately practical, inexpensive test case—not an optimized laboratory supply. The specific TPS5430 module was kept within its intended 15 V-per-rail output limit; no attempt was made to raise its operating voltage.
Generic 18 V, 1 A adapter: the deliberately inexpensive real-world supply
The LM317/LM337 modules use fixed resistor values in this build. Their settings were not adjusted between the switching-supply tests. The toroidal reference rail values and the HP/Delta rail values were documented; the corresponding rail values for the generic-adapter run should not be assumed identical without a direct reading.
How the measurements were made
Signal: sine waves at 100 Hz, 1 kHz, and 10 kHz, with the generator amplitude setting unchanged across the supply tests; only the frequency was selected.
Output load: 300 Ω, measured before the headphone-protection relay.
Keithley 2015: output AC RMS and harmonic-distortion percentage. The harmonic window was 2nd through 10th at 100 Hz and 1 kHz; 2nd through 4th at 10 kHz.
Rigol DS2072A: output waveform, RMS and peak-to-peak voltage. Oscilloscope Vpp includes any transient spikes and pickup that appear within the measurement bandwidth.
Signal source control: THD was also measured directly at the output of the generator, rather than assuming a distortion-free source.
Only the 1 kHz input RMS was directly verified at the amplifier input in the reference series. Consequently, the very small variations in output RMS across frequency should not be presented as a precision frequency-response measurement.
Results: output signal level
Supply and output AC RMS
100 Hz
1 kHz
10 kHz
Toroid + LM317/LM337
381.49 mV
382.25 mV
382.26 mV
HP/Delta + TPS5430 + LM317/LM337
—
382.02 mV
—
Generic 18 V + TPS5430 + LM317/LM337
381.15 mV
382.05 mV
381.73 mV
The output signal level remains within roughly 1 mV across the measured conditions.
Across the toroidal and generic-adapter runs, the Keithley output readings differed by less than 1 mV. The HP/Delta 1 kHz control was similarly close to the toroidal 1 kHz reference. This shows consistent measured output level at the selected test amplitudes, not necessarily identical internal noise or regulation under heavier loads.
Results: harmonic distortion
Supply and measured output THD
100 Hz (2–10)
1 kHz (2–10)
10 kHz (2–4)
Toroid + LM317/LM337
0.208%
0.212%
0.186%
HP/Delta + TPS5430 + LM317/LM337
—
0.212%
—
Generic 18 V + TPS5430 + LM317/LM337
0.208%
0.210%
0.182%
Generator alone
0.226%
0.212%
0.186%
Measured THD at the output. All values include distortion from the external signal generator.
At 1 kHz, the toroid and HP/Delta setups both displayed 0.212% THD, while the generic adapter displayed 0.210%. The difference of 0.002 percentage points is too small to interpret as a meaningful improvement or degradation without repeated runs and an uncertainty analysis. At 100 Hz, the toroid and generic adapter both displayed 0.208%. At 10 kHz, the figures were 0.186% and 0.182%, respectively.
Keithley 2015: 0.212% measured THD at 1 kHz with the toroidal supplyKeithley 2015: 0.212% measured THD at 1 kHz with HP/Delta plus TPS5430Keithley 2015: 0.210% measured THD at 1 kHz with the generic adapter
Critical limitation: The generator alone measured 0.226% THD at 100 Hz, 0.212% at 1 kHz, and 0.186% at 10 kHz. These source figures are comparable to the amplifier-output readings, so the setup cannot isolate the amplifier’s intrinsic THD. Harmonic components can add or cancel in phase, and the direct source measurement was made at a different signal level from the amplifier output. The displayed output THD must therefore be reported as THD of the generator-plus-amplifier measurement chain.
Also, a 10 kHz THD result limited to harmonics 2–4 cannot be compared directly with the 100 Hz and 1 kHz results that include harmonics 2–10 as though the analyzer used the same harmonic span.
What the oscilloscope revealed
Although the Keithley readings were remarkably consistent, the Rigol told a different visual story. The generic adapter produced pronounced narrow spikes and a thicker-looking trace, particularly around the negative portions of the sine wave. This increased the indicated peak-to-peak voltage (Vpp) even when the Keithley AC RMS reading hardly moved.
Frequency
Toroid Vpp
Generic adapter Vpp
100 Hz
1.232 V
1.440 V
1 kHz
1.192 V
1.456 V
10 kHz
1.184 V
1.392 V
100 Hz: oscilloscope comparison
100 Hz output waveform with toroidal power: 1.232 Vpp on the oscilloscope100 Hz with the generic adapter: wider spikes and 1.440 Vpp indicated
10 kHz: oscilloscope comparison
10 kHz waveform with toroidal power: 1.184 Vpp indicated10 kHz waveform with the generic adapter: 1.392 Vpp indicated
Why Vpp is not THD: Peak-to-peak capture responds to occasional fast transients. A harmonic-distortion measurement, by contrast, tracks selected harmonics of the fundamental tone. Switching ripple, broadband noise, ground-loop pickup and probe-induced interference can all alter an oscilloscope trace without necessarily increasing the harmonics reported by the Keithley.
Our earlier probing also showed that much of the observed RF activity depends on the grounding arrangement of the oscilloscope probe: even a shorted tip could display switching-related pickup when connected to the amplifier ground. Therefore, the additional spikes must not be described as a fully verified increase in actual headphone-output noise without a controlled probe-ground baseline and an appropriately band-limited noise test.
An OPA1622 design detail worth investigating
The OPA1622 board in this build uses an unusual local reference point: its dedicated GND/reference pin connects to a midpoint derived from two 10 kΩ resistors between the positive and negative rails, with 0.1 µF bypass capacitors. The OPA1612 has no equivalent dedicated GND pin. This feature may affect how the circuit responds to supply-borne high-frequency interference, but the present test does not establish that it improves THD or suppresses noise. It is a hypothesis for a separate, controlled experiment.
Conclusions and what remains untested
No meaningful change in displayed THD was established: at 100 Hz, 1 kHz and 10 kHz, the measured figures were close across the toroid and generic-adapter supplies.
Output signal levels were highly consistent: Keithley output AC RMS readings clustered around 0.382 V at 300 Ω.
Scope traces were not equivalent: the generic adapter produced noticeably more peak activity and higher Vpp readings.
This is not a noise-floor comparison: a 20 MHz oscilloscope bandwidth limit does not constitute an audio-band noise measurement, and THD alone does not establish THD+N or audible transparency.
The signal generator is a limiting factor: source THD was comparable to the measured amplifier-output THD. A cleaner source and repeatability study would be needed to characterize the amplifier itself.
Bottom line: In this low-level, 300 Ω load experiment, even an inexpensive 18 V wall adapter followed by TPS5430 conversion and LM317/LM337 post-regulation did not produce a clearly measurable THD penalty relative to the toroidal reference. The RF spikes seen on the oscilloscope deserve additional investigation; they are not, by themselves, proof of degraded audio-band distortion.
All measurements and photographs in this report were taken on the actual GraceNote Audio bench setup. This article documents one prototype and one set of test conditions; it is not a universal statement about switching versus linear power supplies.