Wire Resistance & Power Loss Calculator
Estimate DC resistance, voltage drop and heat dissipated in a wire. Switch between meters and feet, mm², diameter and AWG — values convert automatically without changing the selected conductor.
1 · Wire and current
2 · Circuit and explanation
DC model · not a wiring diagramHow the estimate works
R = DC conductor resistance, ρ₂₀ = material resistivity at 20 °C, α = approximate resistance temperature coefficient, L = total conductor length in the selected path, and A = metal cross-sectional area.
Automatic unit conversion: changing the unit switches preserves the physical wire size and length. A fractional AWG is an equivalent gauge, not a standard commercial AWG size. Enter an integer AWG or use the gauge presets for standard sizes.
Real cable: connectors, strand lay, tolerances, alloys, oxidation, and heating can increase resistance. Diameter refers to conductor metal only, excluding insulation; for stranded wire, use the sum of metal areas, not the overall bundle diameter.