GraceNote Audio← Back to Tools
Home / Tools / Circuit Calculators
GRACENOTE ELECTRONICS TOOLKIT

Wire Resistance & Power Loss Calculator

Estimate DC resistance, voltage drop and heat dissipated in a wire. Switch between meters and feet, mm², diameter and AWG — values convert automatically without changing the selected conductor.

1 · Wire and current

At 20 °C: ρ = 0.017241 Ω·mm²/m; α = 0.00393 /°C
5 m = 16.4042 ft
Equivalent diameter and AWG shown here.
Current path
Two conductors = twice the one-way cable length; both carry the same current and use the same area/material. For an unbalanced or speaker cable, choose Out + return.
A
V
Temperature is an input for resistance correction, not a temperature predicted from power loss.
DC resistance · selected current path
0.3448 Ω
Including both forward and return conductors.
Voltage drop1.034 V
Heat dissipated3.10 W
Loss along cable0.621 W/m
Drop relative to supply8.62%

2 · Circuit and explanation

DC model · not a wiring diagram
DC wire resistance model Single conductor or a complete forward and return path through a load, with resistance indicated along the wire. SUPPLY12 V LOAD3 A R₁R₂ Forward conductorReturn conductor Each: 0.1724 Ω
Current path: 10 m of metalAt 20 °Cρ = 0.017241 Ω·mm²/m

How the estimate works

R = ρ₂₀ × [1 + α × (T − 20 °C)] × L / A
Vdrop = I × R   ·   Pheat = I² × R

R = DC conductor resistance, ρ₂₀ = material resistivity at 20 °C, α = approximate resistance temperature coefficient, L = total conductor length in the selected path, and A = metal cross-sectional area.

Automatic unit conversion: changing the unit switches preserves the physical wire size and length. A fractional AWG is an equivalent gauge, not a standard commercial AWG size. Enter an integer AWG or use the gauge presets for standard sizes.

Real cable: connectors, strand lay, tolerances, alloys, oxidation, and heating can increase resistance. Diameter refers to conductor metal only, excluding insulation; for stranded wire, use the sum of metal areas, not the overall bundle diameter.

Heat vs. temperature: The reported watts are electrical heat generated along the entire selected conductor path, not the final wire temperature. The latter depends on insulation, installation, airflow and thermal surroundings. This calculator is not an ampacity or wire-safety rating tool. For AC, skin effect and reactance are not modeled.
Reference material: IEC 60028 · copper resistivity ASTM B258 · AWG sizes HyperPhysics · resistivity table