Transformer Calculator

Estimate transformer AC voltage, current, VA and turns ratio. Compare single, series (center-tapped), and parallel dual-secondary winding configurations.

1 · Secondary configuration

2 · Transformer ratings

V AC

Nominal RMS at rated frequency.

V AC

RMS, nominal under rated load.

A

Rated continuous RMS current.

A

Drawn from the selected output.

%

Extra VA allowance for selection.

Connected secondary output · rated RMS
15.00 V AC
Rated current: 0.50 A RMS
Transformer rating7.50 VA
Load uses60.0%
Planned minimum rating5.63 VA
Ideal primary sizing current*62.5 mA
Load is within the continuous secondary current rating.
Nominal relationships V₁ / V₂ ≈ N₁ / N₂ S (VA) = V₂(RMS) × I₂(RMS)

These are nominal AC winding calculations, not DC power-supply outputs. The primary current shown is the ideal VA/V₁ sizing equivalent, not a prediction of actual no-load or line current.

3 · Functional diagram

Not a mains wiring guide
Isolated mains transformer winding diagram Conceptual transformer diagram showing a primary winding and a selected single, series, or parallel secondary winding arrangement. Not a physical terminal or pinout diagram. ISOLATED AC TRANSFORMER PRIMARY 120 V AC N₁ N₂ OUTPUT 15 V · 0.5 A Symbols show electrical relationships, not physical wire colours or terminals

Single isolated secondary. Ratings use RMS AC values under the conditions specified by the manufacturer.

Primary : one secondary turns ratio8.00 : 1
Primary : connected output ratio8.00 : 1
Nominal load apparent power4.50 VA
Current at load + margin0.375 A
Safety: Mains voltage can be lethal. Use an appropriately rated, safety-approved isolated transformer. This conceptual drawing must not be used to identify physical leads or determine protective fusing. For series or parallel windings, confirm the manufacturer's polarity/phasing markings and wiring instructions before connecting power. Never parallel unmatched windings.

AC vs DC: A rectifier, reservoir capacitor and regulator change voltage, ripple and RMS winding current. Do not use the calculated AC current rating as an equivalent continuous DC current rating.

Measured voltage: Open-circuit RMS voltage is commonly higher than the nameplate full-load secondary voltage. Mains variation, regulation, frequency and heating affect the actual result.

VA vs W: VA is apparent power. Input watts and heating depend on losses and load power factor; this calculator intentionally does not estimate transformer efficiency or rectifier DC output.

Technical references: Hammond · Winding connectionsHammond · Dual-secondary example