Rectifier & Smoothing Capacitor Calculator
Estimate unregulated DC rails after an isolated AC transformer: full-wave rectification, reservoir-capacitor ripple, capacitor sizing, and approximate voltage headroom.
2 · Inputs and results
One complete secondary winding.
Full-wave ripple is twice this frequency.
Total DC current on the single output.
Capacitance across the DC output.
Two conducting diodes in a normal bridge.
Maximum ripple for selecting the capacitor.
Advanced · capacitor voltage rating assumptions
Example assumption: +10% mains.
Example transformer regulation: +15% off-load.
For dual ± rails, the model is calculated per rail, assuming equal positive and negative load currents and equal reservoir capacitances. n = two diode drops for a single-secondary bridge, one diode drop per rail for the center-tap configurations.
3 · Connection diagram
Functional schematic · not pinoutSingle secondary full-wave bridge with a reservoir capacitor connected across +DC and 0 V.
4 · Practical checks
| Nominal peak at capacitor | — |
| Estimated high-line / unloaded peak | — |
| Nominal ripple, worst at low C | — |
| Idealized per-rail DC load power | — |
| Conducting diode drops | — |
AC mains wiring, protection, fusing and isolation are not shown. Do not apply these circuits directly to non-isolated mains. Capacitors can retain dangerous charge after power-off.
Capacitor voltage selection uses the high-line and off-load-rise assumptions entered above, assumes essentially no diode drop at light/no load, then adds another 20% screening margin. Verify actual transformer regulation, mains range, surge conditions and capacitor limits. It is not a certified voltage rating.